Model |
Nominal Capacity |
Water Flow |
| |
|
|
Hot Water |
Cold Water |
| |
kW |
Btu/Hr |
PSIG |
USGPM |
PSIG |
USGPM |
| M 180 |
53 |
180,000 |
0.40 |
7.93 |
1.10 |
55.48 |
| M 300 |
88 |
300,000 |
0.90 |
10.57 |
2.50 |
79.25 |
| M 500 |
146 |
500,000 |
1.30 |
14.53 |
3.20 |
95.10 |
Nominal values are based on 60°C (140°F) temperature difference
between incoming heating and heated water
|
Model |
Heat Transfer Area |
Connection Shell |
Connection Tubes |
| |
|
|
|
|
| |
m2 |
ft2 |
in |
in |
| M 180 |
0.44 |
4.70 |
1-1/2" |
1" |
| M 300 |
0.84 |
9.00 |
1-1/2" |
1" |
| M 500 |
1.56 |
16.80 |
1-1/2" |
1" |
|
Design Parameters |
TUBES |
SHELL |
| TEMPERATURE |
406°F (208°C) |
406°F (208°C) |
| PRESSURE |
150 PSI (1.03MPa) |
150 PSI (1.03MPa) |
Specifications may change without notice. Contact